The voltage measured between legs is dependent on how your system is supplied and the type of transformer used. The comments below were added after this Forum discussion was archived as a Knowledge Base article ( add your comment). Doing it over I would split my panels so that I had one for single phase in which I could use all the slots and one for three phase in which I also could use all the slots.

220 volt single phase wiring diagram

Therefore I have a lot of open single slots in my electric panel. I just have to be careful not to use the wild leg in a single phase application. I run single phase 120v, 220v and three phase from the same panel. Around here it is what you would get unless you requested wye transformers. The interesting thing is that in this article, the delta system is not the norm. A quick phone call to your power company would clarify exactly what voltage and which configuration you have.

220 volt single phase wiring diagram

Re my terminology comment, it's been a while since I had the discussion with my electrician, but I *think* the two flavors of 2**v power are 208v three phase Wye, and 240v three phase Delta. I have 240v three phase Delta config at my shop, with no neutral (I cannot get 120v from it). Two things come to mind in this situation: use of terminology, and Delta vs Wye configuration. In that case, any single phase to neutral will measure 240 volts in the UK/Ireland, which is how we wire things here. I never would have imagined such a thing.Īre you in Britain or Europe? If so, the 3-phase supply is measured phase to phase - 415 volts 50Hz in the UK/Ireland or 380 volts 50Hz in most of mainland Europe. It took my friend several attempts to get me to understand shared neutrals in single phase circuitry as an example. Electricity can be a very basic and also an extremely complex topic. I'm going to ask him to explain to me why that would occur. I have a very good friend who is a high voltage industrial electrician. I'm surprised that all 3 legs in a 240v service are not balanced by the transformer on the pole. Over the years I've seen that configuration again and so described the situation as I did. When we used any 2 legs we ended up with 208v. Years ago I lived in a place where we had either 220v or 240v 3-phase (way too long ago to remember which) power. I simply based my comments on my experience. The current draw will be different at each setting, requiring different wire sizes to work properly. Most three phase motors can be configured to run on 208, 220/240 and 440/480. This may require that you change the motor leads as per the wiring diagram in each motor. Usually this is used for lighting such as in a large department store but can be used for industrial, providing your motors are rated for such. 208 three phase is different in that each leg is equal in voltage and usually more stable (not dirty) - between any two there is 208 volts. Voltage fluxes can be common, so what is 240 today might be 237 tomorrow. Depends on your power source as to how dirty this might be. A motor rated for 220 volt three phase would run on the 240 volts. He would use the two stable lines and have 240 volts, not 208. If he actually has a 240 volt three phase service (a delta bank), there will be 240 volts between any two legs, however if you check between the line and ground, one leg will be "wild," that is it will have about 175 volts on it.

#220 volt single phase wiring diagram full

If this motor is to be operated at full load all the time, like a compressor, I would suggest getting a buck/boost transformer to change the voltage to the proper range. If it is rated for 220 VAC, then you can operate it in a range of 200-242 VAC without too many problems.

220 volt single phase wiring diagram

Most motors can tolerate a 10% voltage swing without harm. Still using two legs and a neutral of the 3 ph system will yield 240 single phase. If he's in Europe, he may actually have a 240 VAC 3 PH system. You will actually be running on 208 volts, but that is within range of the motor tolerances. Yes, you can run a 240v single phase motor on two legs of a 240v three phase service. I was wondering if I can run a 240 single phase motor off of 2 legs of the three phase panel? Also, what if the motor is rated at 220 single phase - will using 2 legs of a 240 3 phase feed hurt it?